Logo

ISO 5151:2017

Current Revision

Non-ducted air conditioners and heat pumps - Testing and rating for performance

$250.00

$250.00

$425.00

Modifications (Amendments, Corrigenda, Errata, etc.)

$23.00

$23.00

$39.10


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

ISO 5151:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.

ISO 5151:2017 is applicable to the following equipment:

- non-ducted air-cooled air conditioners and non-ducted air-to-air heat pumps; or

- ducted air conditioners and/or ducted heat pumps rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa.

ISO 5151:2017 is limited to:

- residential, commercial and industrial single-package and split-system air conditioners and heat pumps;

- factory-made, electrically driven and use mechanical compression;

- utilizing single, multiple and variable capacity components;

- multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.

The requirements of testing and rating contained in this document are based on the use of matched assemblies.

ISO 5151:2017 is not applicable to the rating and testing of the following:

a) water-source heat pumps or water cooled air conditioners;

b) multi-split-system air conditioners and air-to-air heat pumps (follow ISO 15042 for the testing of such equipment);

c) mobile (windowless) units having a condenser exhaust duct;

d) individual assemblies not constituting a complete refrigeration system;

e) equipment using the absorption refrigeration cycle;

f) ducted equipment except for those specified in this clause (follow ISO 13253 for the testing of such equipment).

ISO 5151:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

NOTE Throughout this document, the terms "equipment" and "systems" mean "air conditioners" and/or "heat pumps".


SDO ISO: International Organization for Standardization
Document Number ISO 5151
Publication Date Not Available
Language en - English
Page Count
Revision Level
Supercedes
Committee ISO/TC 86/SC 6
Publish Date Document Id Type View