Logo

IEEE C95.1-2005

Current Revision

IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz

$150.00


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

Revision Standard - Superseded. Recommendations to protect against harmful effects in human beings exposed to electromagnetic fields in the frequency range from 3 kHz to 300 GHz are provided in this standard. These recommendations are intended to apply in controlled environments and for general population exposure. These recommendations are not intended to apply to the exposure of patients by or under the direction of physicians and medical professionals.
Recommendations are made to protect against established adverse health effects in human beings associated with exposure to electric, magnetic and electromagnetic fields in the frequency range of 3 kHz to 300 GHz. The recommendations are expressed in terms of basic restrictions (BRs) and maximum permissible exposure (MPE) values. The BRs are limits on internal fields, specific absorption rate (SAR), and current density; the MPEs, which are derived from the BRs, are limits on external fields and induced and contact current. The recommendations, which protect against effects associated with electrostimulation and tissue and wholebody heating, are intended to apply to all human exposures except for exposure of patients by, or under the direction of, physicians and medical professionals. These recommendations are not intended for the purpose of preventing interference with medical and other devices that may exhibit susceptibility to radio frequency (RF) fields. The recommendations at 300 GHz are compatible with existing recommendations for safe exposure in the infrared frequency range, which begins at 300 GHz, cf., ANSI Z136.1-2000 [B7]1, ICNIRP guidelines [B63], and IEC 60825-1 [B65]. IEEE Std C95.6-20022 is the applicable standard for use at frequencies below 3 kHz.
The purpose of this standard is to provide exposure limits to protect against established adverse effects to human health induced by exposure to RF electric, magnetic and electromagnetic fields over the frequency range of 3 kHz to 300 GHz.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number C95.1
Publication Date April 19, 2006
Language en - English
Page Count 238
Revision Level
Supercedes
Committee International Committee on Electromagnetic Safety
Publish Date Document Id Type View
April 19, 2006 C95.1-2005 Revision
April 27, 1992 C95.1-1991 Revision
Sept. 1, 1982 C95.1-1982 Revision