IEEE C62.36-2016

Current Revision

IEEE Standard Test Methods for Surge Protectors and Protective Circuits Used in Information and Communications Technology (ICT) Circuits, and Smart Grid Data Circuits

$158.00

$198.00

$320.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

Revision Standard - Active. Surge protectors for application on multiconductor balanced or unbalanced information and communications technology (ICT) circuits and smart grid data circuits are addressed in this standard. These surge protectors are designed to limit voltage surges, current surges, or both. The surge protectors covered are generally multiple-component series or parallel combinations of linear or nonlinear elements, packaged or organized for the purpose of limiting voltage, current, or both. The methods of testing and criteria (where appropriate) for the characteristics and ratings of surge protectors used in ICT circuits and smart grid data circuits are also described in this standard. Packaged single gas tube, air gap, varistor, or avalanche junction surge-protective components are not covered by this standard, but rather are covered by IEEE Std C62.31, IEEE Std C62.32, IEEE Std C62.33, and IEEE Std C62.35, respectively. Specifically excluded from this standard are test methods for low-voltage power circuit applications. For protection of wire-line communication facilities under the specialized conditions found at power stations, consult IEEE Std 487.
This standard applies to surge protectors for application on multiconductor balanced or unbalanced information and communications technology (ICT) circuits and smart grid data circuits. These surge protectors are designed to limit voltage surges, current surges, or both. The surge protectors covered are generally multiple-component series or parallel combinations of linear or nonlinear elements, packaged or organized for the purpose of limiting voltage, current, or both. This standard describes the methods of testing and criteria (where appropriate) for the characteristics and ratings of surge protectors used in ICT circuits and smart grid data circuits. This standard is not intended to cover packaged single gas tube, air gap, varistor, avalanche junction, or self-restoring current limiter surgeprotective components (SPCs), which are covered by IEEE Std C62.31 [B20], IEEE Std C62.32 [B21], IEEE Std C62.33 [B22], IEEE Std C62.35 [B23], and IEEE Std C62.39 [B24], respectively. Specifically excluded from this standard are test methods for low-voltage power circuit applications. For protection of wire-line communication facilities under the specialized conditions found at power stations, consult IEEE Std 487 [B16] series of documents.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number C62.36
Publication Date Nov. 2, 2016
Language en - English
Page Count 150
Revision Level
Supercedes
Committee Surge Protective Devices/Low Voltage
Publish Date Document Id Type View
Nov. 2, 2016 C62.36-2016 Revision
July 9, 2014 C62.36-2014 Revision
Oct. 13, 2000 C62.36-2000 Revision
March 31, 1995 C62.36-1994 Revision
Feb. 10, 1992 C62.36-1991 Revision