Revision Standard - Superseded. This standard applies to metal-oxide surge arresters (MOSAs) designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz power circuits (>1000 V) by passing surge discharge current and automatically limiting the flow of system power current. This standard applies to devices for separate mounting and to devices supplied integrally with other equipment. The tests demonstrate that an arrester can survive the rigors of reasonable environmental conditions and system phenomena while protecting equipment and/or the system from damaging overvoltages caused by lightning, switching, and other undesirable surges.
This standard applies to metal-oxide surge arresters (MOSAs) designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz power circuits (>1000 V) by passing surge discharge current and automatically limiting the flow of system power current. This standard applies to devices for separate mounting and to devices supplied integrally with other equipment. NOTE--These tests demonstrate that an arrester can survive the rigors of reasonable environmental conditions and system phenomena while protecting equipment and/or the system from damaging overvoltages caused by lightning, switching, and other undesirable surges.
To provide improved procedures for the testing of metal-oxide arresters to better assure product quality and integrity. This will be accomplished by refining existing test procedures and adding new requirements that better demonstrate arrester capability. Where new test requirements more suitably or more comprehensively demonstrate the capability of arresters than do existing requirements, existing requirements may be eliminated.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number C62.11
Publication Date March 22, 2006
Language en - English
Page Count 64
Revision Level
Supercedes
Committee Surge Protective Devices Committee
Publish Date Document Id Type View
Sept. 24, 2020 C62.11-2020 Revision
Dec. 20, 2012 C62.11-2012 Revision
March 22, 2006 C62.11-2005 Revision
Aug. 2, 1999 C62.11-1999 Revision
May 13, 1994 C62.11-1993 Revision
July 24, 1987 C62.11-1987 Revision