IEEE C57.105-1978

Historical Revision

IEEE Guide for Application of Transformer Connections in Three-Phase Electrical Systems

$92.00


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

New IEEE Standard - Superseded. The characteristics of the various transformer connections and possible operating problems under normal or abnormal conditions are treated for three-phase distribution systems. These systems are characterized by primary voltages up to and including 34.5 kV, usually have a preponderance of connected transformers with low-voltage windings below 1000 V, and furnish electric service to consumers. All combinations of Delta and Y, grounded and ungrounded, T connected, zigzag, and certain special connections are considered. Only two-winding transformers are included. Phasing procedures and loading practices are not covered.
This guide concerns transformer connections in 3-phase distribution systems. Distribution systems are characterized by primary voltages up to and including 34.5 kV, usually have a preponderance of connected transformers with low voltage windings below 1000 V and furnish electric service to consumers. The characteristics of the various transformer connections and possible operating problems under normal or abnormal conditions are treated. All combinations of Δ and Y, grounded and ungrounded, T connected, zigzag, and certain special connections are considered. Only two-winding transformers are included. Phasing procedures and loading practices are not covered. Guides for loading of oil-immersed and dry-type transformers are available in publications of the American National Standards Institute: American National Standard C57.91-1974, Appendix to C57.12.00-1973, Guide for Loading Mineral Oil-Immersed Overhead-Type Distribution Transformers with 55°C or 65°C Average Winding Rise; American National Standard C57.92-1962, Appendix to C57.12 Standards, Guide for Loading Oil-Immersed Distribution and Power Transformers; and American National Standard C57.96-1959, Appendix to C57.12 Standards, Guide for Loading Dry-Type Distribution and Power Transformers, respectively.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number C57.105
Publication Date Oct. 20, 1978
Language en - English
Page Count 39
Revision Level
Supercedes
Committee Transformers
Publish Date Document Id Type View
March 31, 2020 C57.105-2019 Revision
Oct. 20, 1978 C57.105-1978 Revision