IEEE C57.100-1986

Historical Revision

IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers

$92.00


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

New IEEE Standard - Superseded. The object of this test procedure is to establish a uniform method for investigating the effect of operating temperature on the life expectancy of oil-immersed distribution transformers. It is intended to give a direct evaluation of the composite insulation system of an oil-immersed distribution transformer, tested as an integral unit. It is to be noted that the oil in which the transformer is immersed is to be considered a part of the insulation system. It is the intent of the procedure to provide that each component of the insulation structure operate during the test under conditions that are, as nearly as possible, the same as those that it would encounter in service. Thus, it is intended that each component be evaluated in accordance with its actual function.
This test procedure is intended to give a direct evaluation of the composite insulation system of an oil-immersed distribution transformer, tested as an integral unit. It is to be noted that the oil in which the transformer is immersed is to be considered a part of the insulation system. It is intent of the procedure to provide that each component of the insulation structure operate during the test under conditions that are, as nearly as possible, the same as those that it would encounter in service. Thus, it is intended that each component be evaluated in accordance with its actual function.
The object of this test procedure is to establish a uniform method for investigating the effect of operating temperature on the life expectancy of oil-immersed distribution transformers. The results may be used, for example, to: 1) Provide data for selection of a limiting hottest-spot temperature for rating purposes, which will provide reasonable life expectancy under normal operating conditions 2) Provide data that may serve as the basis of a guide for loading 3) Permit the comparative evaluation of a proposed insulation system, with reference to a system that has proven to be acceptable in service

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number C57.100
Publication Date Sept. 15, 1986
Language en - English
Page Count 12
Revision Level
Supercedes
Committee Transformers
Publish Date Document Id Type View
March 24, 2023 C57.100-2022 Revision
Jan. 27, 2012 C57.100-2011 Revision
Oct. 7, 1999 C57.100-1999 Revision
Sept. 15, 1986 C57.100-1986 Revision