Revision Standard - Active. Described in this guide are protective relay applications involving electric service to consumers that requires a transformation between the utility's supply voltage and the consumer's utilization voltage. It describes the factors that need to be considered in the design of adequate protection facilities, outlines modern relay practices, and provides several examples of the protection of typical utility-consumer interconnections.
This guide contains information on a number of different protective relaying practices for the utility-consumer interconnection. It is intended to cover applications involving service to a consumer that normally requires a transformation between the utility's supply voltage and the consumer's utilization voltage. Interconnections supplied at the utilization voltage are not covered. This guide is not intended to supplant specific utility or consumer practices, procedures, requirements, or any contractual agreement between the utility and consumer. The examples of interconnection protection of varying complexities that have been provided are used for illustrative purpose only and do not necessarily represent the preferred protection under all conditions. This guide addresses consumers, with or without conventional generation, that are connected to utility subtransmission or transmission circuits. The specific control schemes associated with generation are not addressed. It is not intended to apply to consumer generation connected to utility distribution circuits. For these interconnections, refer to IEEE Std 1547(TM)-2003.
The primary purpose of this guide is to help those who are responsible for the application of protective relaying for the electrical interconnection between utility and consumer systems. It is anticipated that representatives of the utility, the consumer, and their consultants who are responsible for the specification, design, and operation of the interconnection will use this guide. Recognizing the diverse audience being addressed, background information is included in a bibliography to direct the reader to more complete treatment of the material.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number C37.95
Publication Date May 5, 2014
Language en - English
Page Count 70
Revision Level
Supercedes
Committee Power System Relaying and Control
Publish Date Document Id Type View
May 5, 2014 C37.95-2014 Revision
April 17, 2003 C37.95-2002 Revision
Nov. 3, 1989 C37.95-1989 Revision