IEEE C37.015-2009

Historical Revision

IEEE Guide for the Application of Shunt Reactor Switching

$94.00


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

Revision Standard - Superseded. This application guide applies to ac high-voltage circuit breakers rated for shunt reactor switching. The guide covers the specific cases of switching directly grounded shunt reactors, ungrounded shunt reactors and shunt reactors grounded through a neutral reactor. Directly grounded reactors are common on systems having a voltage of 60 kV and above, while ungrounded reactors are commonly applied on systems having a voltage below 60 kV. Schemes where the reactor is grounded through a neutral reactor are usually only applied on systems having a voltage of 60 kV and above. Whereas this application guide is directed towards circuit breakers, it is recognized and accepted that other switching devices such as high voltage load break switches and circuit switchers are capable of shunt reactor switching and this guide may be applied as appropriate.
This application guide applies to ac high-voltage circuit breakers rated for shunt reactor switching. The guide covers the specific cases of switching directly grounded shunt reactors, ungrounded shunt reactors, and shunt reactors grounded through a neutral reactor. Directly grounded reactors are common on systems having a voltage of 60 kV and above, whereas ungrounded reactors are commonly applied on systems having a voltage below 60 kV. Schemes where the reactor is grounded through a neutral reactor are usually applied only on systems having a voltage of 60 kV and above. Whereas this application guide is directed toward circuit breakers, it is recognized and accepted that other switching devices such as high-voltage load break switches and circuit switchers are capable of shunt reactor switching and this guide may be applied as appropriate.
This guide is intended for general use in the application of ac high-voltage circuit breakers for shunt reactor current switching. The current to be interrupted is generally less than 300 A rms; however, shunt reactor switching imposes a unique and severe duty on the connected system and the circuit breaker. Successful interruption is the result of a complex interaction between the circuit breaker and the circuit; this interaction can result in significant overvoltages. The purpose of the guide is to describe, principally for the benefit of the user, the shunt reactor switching duty, the overvoltages generated, and the control of those overvoltages. The guide furthere details the specification of circuit breakers and procedures to predict field performance based on test data.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number C37.015
Publication Date Feb. 12, 2010
Language en - English
Page Count 70
Revision Level
Supercedes
Committee Switchgear
Publish Date Document Id Type View
March 16, 2018 C37.015-2017 Revision
Feb. 12, 2010 C37.015-2009 Revision
Nov. 30, 1993 C37.015-1993 Revision