Logo

IEEE 998-2012

Current Revision

IEEE Guide for Direct Lightning Stroke Shielding of Substations

$253.00


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

Revision Standard - Inactive-Reserved. Design information for the methods historically and typically applied by substation designers to reduce direct lightning strokes to equipment and buswork within substations is provided. Two approaches, the classical empirical method and the electrogeometric model, are presented in detail. A third approach, which involves the use of non-conventional lightning terminals and related design methods, is also reviewed.
This guide identifies and discusses design procedures to provide direct stroke shielding of outdoor distribution, transmission, and generating plant substations. Known methods of shielding from direct strokes were investigated during the preparation of this guide, and information is provided on two methods found to be widely used: a) The classical empirical method b) The electrogeometric model A third approach, which involves the use of non-conventional lightning terminals and related design methods, is also reviewed. This guide does not purport to include all shielding methods that may have been developed. The guide also does not address protection from surges entering a substation over power or communication lines or the personnel safety issues. Users of this guide should thoroughly acquaint themselves with all factors that relate to the design of a particular installation and use good engineering judgment in the application of the methods given here, particularly with respect to the importance and value of the equipment being protected.
Direct strokes from lightning can damage substation equipment and bus work. To protect equipment, substation engineers can install direct stroke lightning shielding. This guide is intended to provide engineers with information pertaining to the interception of damaging direct lightning strokes to outdoor substations. This guide includes methods that have been utilized for decades as well as some that have been developed more recently. The general nature of lightning is discussed, and the problems associated with providing shielding from direct strokes are described. Tables, formulas, and examples are provided to calculate whether substation equipment is effectively shielded from direct lightning strokes. Because of the unpredictability of lightning and the costs associated with damage from direct lightning strokes, research into lightning phenomenon is ongoing. This guide includes descriptions of four nonconventional modeling methods for lightning interception, as well as a review of active lightning terminals. The four non-conventional methods are in various stages of development and are presented as a sample of the continuing research in direct lightning stroke shielding. These methods have potential to be used as design models for substation direct lightning stroke shielding in the future. A bibliography for further study is included to provide the substation shielding engineer with additional lightning research.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number 998
Publication Date April 30, 2013
Language en - English
Page Count 227
Revision Level
Supercedes
Committee Substations Committee
Publish Date Document Id Type View
April 30, 2013 998-2012 Revision
Nov. 30, 1995 998-1996 Revision