Logo

IEEE 501-1978

Current Revision

IEEE Standard Seismic Testing of Relays

$56.00


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

New IEEE Standard - Superseded. This is a standard for developing data related to the seismic capabilities of relays. This standard compliments ANSI/IEEE Std 344-1975, Recommended Practices for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations, which provides general guidelines for developing data related to seismic qualification of equipment used in nuclear generating plants. Data must be developed by testing rather than analytical means since protective relays fall into the category of complex devices as described in Section 5 of ANSI/IEEE Std 344-1975; however, analysis may be used in data reduction, in reconciling response spectra, in justifying methods of evaluating changes, and in justifying seismic qualifications of relays of similar construction. While aging is recognized as a potential influence on the seismic capability of relays, insufficient definition presently exists to permit realistic simulation of end-of-life for various relays. When applicable definition of the various degrading factors and methods of accelerating the effect of these factors is developed in other related standards, they should be considered in the previbration preparation. It should be emphasized that while a primary purpose in preparing this standard was to cover the application of relays to nuclear generating plants, the standard is not restricted to this application. This standard may be applied to any area in which the seismic response of relays is a design consideration.
This standard specifies the procedures t o be used in the seismic testing of relays used in power system facilities. The standard is concerned with the determination of the seismic fragility level of relays and also gives recommendations for proof testing.
The purpose of this standard is to establish procedures for determining the seismic capabilities of protective and auxiliary relays. These procedures employ what has been called fragility testing in ANSI/IEEE Std 344-1975, Recommended Practices for Seismic Qualification of Class IE Equipment for Nuclear Power Generating Stations. In order to define the conditions for fragility testing of relays, parameters in three separate areas must be specified. In general they are: (l) The electrical settings and inputs to the relay, and other information to define its conditions during the test. (2) The change in state, deviation in operating characteristics or tolerances, or other change of performance of the relay which constitutes failure. (3) The seismic vibration environment to be imposed during the test.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number 501
Publication Date April 28, 1978
Language en - English
Page Count 20
Revision Level
Supercedes
Committee
Publish Date Document Id Type View
April 28, 1978 501-1978 Revision