Revision Standard - Superseded. Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby power applications are provided. This recommended practice also provides guidance to determine when batteries should be replaced. This recommended practice is applicable to all stationary applications. However, specific applications, such as emergency lighting units and semiportable equipment, may have other appropriate practices and are beyond the scope of this recommended practice.
This recommended practice provides maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby power applications. It also provides guidance to determine when batteries should be replaced. This recommended practice is applicable to all stationary applications. However, specific applications, such as emergency lighting units and semiportable equipment, may have other appropriate practices and are beyond the scope of this recommended practice. Sizing, installation, qualification, other battery types, and application are also beyond the scope of this recommended practice. This recommended practice does not include any other component of the dc system, or surveillance and testing of the dc system, even though the battery is part of that system. Preoperational and periodic dc system tests of chargers and other dc components may require that the battery be connected to the system. Details for these tests will depend on the requirements of the dc system and are beyond the scope of this recommended practice.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number 450
Publication Date May 31, 1995
Language en - English
Page Count 32
Revision Level
Supercedes
Committee Energy Storage & Stationary Battery Committee
Publish Date Document Id Type View
Feb. 25, 2011 450-2010 Revision
April 3, 2003 450-2002 Revision
May 31, 1995 450-1995 Revision
Nov. 30, 1974 450-1975 Revision
July 7, 1972 450-1972 Revision