IEEE 367-1987

Historical Revision

IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault

$208.00


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

Revision Standard - Superseded. Guidance is provided for the calculation of interfering voltages and their appropriate reduction from worst-case values for use in wire-line telecommunication protection design. Information is also included for the determination of the fault current and earth-return current levels; their probability, waveform, and duration; and the impedance to remote earthing points used in these ground potential rise (GPR) and longitudinally induced voltage calculations. The zone of influence of the power station GPR; the calculation of the inducing currents; the mutual impedance between power and wire-line telecommunication facilities and shield factors; and the channel time requirements for wire-line telecommunication facilities where noninterruptible channels are required for protective relaying and other purposes are covered.
Difficulties are experienced by telecommunication, protection, and relay engineers in determining the "appropriate" values of power station ground potential rise (GPR) or the longitudinally induced voltages (LI) into wire-line telecommunications facilities (or both) including their probability, waveform, and duration, which are to be used in developing the specifications for systems and component protection. Suitably rated protection devices are required for personnel safety and for the protection and continuity of service for wire-line facilities that either enter electric power stations or that are otherwise exposed to the influence of high-electric power circuits. (See ANSI/IEEE Std 487-1980 [51]) This standard provides guidance for the calculation of these interfering voltages and guidance for their appropriate reduction from worst-case values for use in wire-line telecommunication protection design. Information is also included for the determination of (1) The fault current and earth return current levels; their probability, waveform, and duration; and the impedance to remote earthing points used in these GPR and LI calculations as well as the effective X/R ratio. (2) The zone of influence of the power station GPR. (3) The calculation of the inducing currents, the mutual impedance between (4) The channel time requirements for wire-line telecommunication facilities power and wire-line telecommunication facilities, and shield factors. where noninterruptible channels are required for protective relaying, etc.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number 367
Publication Date April 29, 1988
Language en - English
Page Count 165
Revision Level
Supercedes
Committee Power System Communications and Cybersecurity
Publish Date Document Id Type View
May 21, 2012 367-2012 Revision
Nov. 30, 1996 367-1996 Revision
April 29, 1988 367-1987 Revision