Revision Standard - Superseded. Background on light flicker caused by fluctuations in power demands of variable loads is presented in this recommended practice. A flicker measurement method is presented using a meter that is completely described in IEC 61000-4-15. The short-term (Pst) and long-term (Plt) flicker indices used for the analysis of flicker data are defined. Flicker limits for various voltage levels are presented. An assessment procedure for evaluating flicker compliance against emission limits is described. Methodologies to analyze background flicker to identify the flicker contribution of single loads are also presented.
This recommended practice provides background on light flicker caused by fluctuations in power demands of variable loads. A flicker measurement method is presented using a meter that is completely described in IEC 61000-4-15. The short-term (Pst) and long-term (Plt) flicker indices used for the analysis of flicker data are defined. Flicker limits for various voltage levels are presented. An assessment procedure for evaluating flicker compliance against emission limits is described. Methodologies to analyze background flicker to identify the flicker contribution of single loads are also presented. The document provides ways to estimate flicker levels at the Point of Common Coupling (PCC) depending on the type of the load. This document includes example terms and language that can be the basis for defining relative responsibilities and assessment methods for customer installations that may cause flicker.
The purpose of this document is to provide guidance to system operators, owners, and engineers who are responsible for providing electrical service to installations that cause voltage fluctuations. It provides guidance on the principles and methodology that can be used to determine requirements for connecting fluctuating loads to both radial and network systems. Methods for determining appropriate flicker planning levels and emission limits for fluctuating loads as well as those that create rapid voltage changes are provided.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number 1453
Publication Date Oct. 30, 2015
Language en - English
Page Count 74