Logo

IEEE 122-1991

Current Revision

IEEE Recommended Practice for Functional and Performance Characteristics of Control Systems for Steam Turbine-Generator Units

$162.00


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

Document Preview Not Available...

Revision Standard - Inactive-Withdrawn. Minimum functional and performance characteristics related to speed/load-control systems for steam turbine-generator units that may be interconnected on a power system are recommended. The recommendations apply to the following types of steam turbines, rated at 500 kW and larger, intended to drive electric generators at constant speed without initial steam-pressure control, exhaust steam-pressure control, or either: (1) condensing or noncondensing turbines without initial steam-pressure control, exhaust steam-pressure control, including turbines used with reheat, regenerative feedwater heaters, or both; (2) condensing or noncondensing turbines with initial and/or exhaust steam-pressure control, including turbines used with reheat, regenerative feedwater heaters, or both; (3) automatic extraction and/or induction and mixed-pressure turbines. Emergency governors, other overspeed control devices, and, in general, devices that are not responsive to speed, are not covered.
These recommendations apply to the following types of steam turbines, rated at 500 kW and larger, intended to drive electric generators at constant speed: 1) Condensing or noncondensing turbines without initial steam-pressure control, exhaust steam, pressure control, or either, including turbines used with reheat, regenerative feedwater heaters, or both. (See Figs 1 and 2). 2) Condensing or noncondensing turbines with initial steam-pressure control, exhaust steam-pressure control, or both, including turbines used with reheat, regenerative feedwater heaters, or both. [See Figs 3, 7, 8(a), and 8(b)]. 3) Automatic extraction, induction, or both, and mixed-pressure turbines. [See Figs 4, 5, and 8(c)].
The purpose of this recommended practice is to recommend functional and performance characteristics related to speed/load-control systems for steam turbine-generator units that may be interconnected on a power system, such that this recommended practice may be included in prime-mover purchase specifications.

SDO IEEE: Institute of Electrical and Electronics Engineers
Document Number 122
Publication Date April 15, 1992
Language en - English
Page Count 28
Revision Level
Supercedes
Committee Energy Development & Power Generation
Publish Date Document Id Type View
April 15, 1992 122-1991 Revision
July 22, 1985 122-1985 Revision