Wire connectors (Trinational standard with NMX-J-543-ANCE-2025 and UL 486A-486B)
This is the harmonized ANCE, CSA Group, and ULSE standard for Wire Connectors . It is the fifth edition of NMX-J-543-ANCE, the seventh edition of CSA C22.2 No. 65, and the fourth edition of UL 486A-486B. This edition of NMX-J-543-ANCE supersedes the previous edition published on July 20, 2023. This edition of CSA C22.2 No. 65 supersedes the previous edition published on January 11, 2013 and April 27, 2018. This edition of UL 486A-486B supersedes the previous edition published on April 27, 2018. This harmonized standard was prepared by the Association of Standardization and Certification (ANCE), CSA Group, and ULSE Inc. (ULSE). The efforts and support of the Technical Harmonization Committee for Connectors, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. The present Mexican standard was developed by the SC 20D – Conectadores part of the CT 20 – Conductores from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the connectors manufacturers and users. This standard was reviewed by the CSA Integrated Committee on Electrical Connectors, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group.
This Standard applies to single-polarity connectors for use with all alloys of copper or aluminum, or copper-clad aluminum conductors, or all three, for providing contacts between current-carrying parts, in accordance with the Canadian Electrical Code, Part I, CSA C22.1, in Canada, the National Electrical Code, NFPA 70, in the United States of America, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico, as follows: NOTE: Copper-clad aluminum conductors are for use only in the United States in accordance with the National Electrical Code, NFPA 70.
Connectors covered by this Standard are also suitable for use with conductors that are prepared using ferrules evaluated in accordance with CSA C22.2 No. 291-14 / UL 486F, or wire connector adapters evaluated in accordance with this Standard, under the following conditions
This Standard is intended for connectors suitable for use with conductors in the size ranges as follows
This Standard is intended for connectors suitable for currents not exceeding the ampacity of insulated conductors rated 75 °C or 90 °C in accordance with the rating of the connector, if provided.
These requirements cover insulated connectors, insulating caps, and covers intended for use at 2 000 volts or less and uninsulated connectors for use in general use circuits rated 35 000 volts nominal or less. In Canada, uninsulated connectors may also be used in applications up to 5 000 volts phase-to-phase where allowed and installed in accordance with Section 36 of the Canadian Electrical Code, Part I, CSA C22.1. For products intended for use in Canada, general requirements are given in CSA C22.2 No. 0.
This Standard does not apply to
| SDO | CSA: Canadian Standards Association |
| Document Number | |
| Publication Date | Jan. 1, 2025 |
| Language | en - English |
| Page Count | 109 |
| Revision Level | |
| Supercedes | |
| Committee |