Backflow preventers and vacuum breakers
This is the seventh edition of the CSA B64 Series, Backflow preventers and vacuum breakers . It supersedes the previous editions, published in 2011, 2007, 2001, 1994, 1988, and 1976. This edition consists of the following Standards
This Standard specifies definitions, general requirements, test methods, markings, and instructions that are common to some or all of the Standards in the CSA B64 Series.
This Standard is not a complete Standard in itself and is intended to be used in conjunction with one of the Standards in the CSA B64 Series to form a complete Standard for a particular type of vacuum breaker or backflow preventer.
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with each Standard in the Series; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standards in the Series. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
This Standard is written in SI units, which are the units of record for the purposes of this Standard. For conversion tables, see Annex A. Vacuum is expressed in pressure below ambient. All pipe sizes are shown as nominal pipe sizes (NPS). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers atmospheric vacuum breakers (AVB). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers pressure vacuum breakers (PVB). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers spill-resistant pressure vacuum breakers (SRPVB). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers manufactured vacuum breakers, air space type (ASVB). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers hose connection vacuum breakers (HCVB). -------------------------------------------------------------------------------------------------------------------------------- CSA B64.2.1:21 -Hose connection vacuum breakers (HCVB) with manual draining feature Scope 1.1 This Standard covers hose connection vacuum breakers (HCVB) that incorporate a draining feature that requires manual operation. -------------------------------------------------------------------------------------------------------------------------------- CSA B64.2.1.1:21 -Hose connection dual check vacuum breakers (HCDVB)
This Standard covers hose connection vacuum breakers that have two check valves (HCDVB) and that incorporate a draining feature that requires manual operation. The second (downstream) check valve is field-testable. -------------------------------------------------------------------------------------------------------------------------------
This Standard covers dual check valve backflow preventers with an atmospheric port (DCAP). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers dual check valve backflow preventers with an atmospheric port for carbonators (DCAPC). ------------------------------------------------------------------------------------------------------------------------------
This Standard covers reduced pressure principle backflow preventers specifically designed for use in fire protection systems (RPF). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers double check valve backflow preventers specifically designed for use in fire protection systems (DCVAF). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers dual check valve backflow preventers designed for use in fire protection systems (DuCF). -------------------------------------------------------------------------------------------------------------------------------
This Standard covers vacuum breakers for use on laboratory faucets. -------------------------------------------------------------------------------------------------------------------------------
This Standard covers dual check valve backflow preventers with an intermediate vent (DuCV). Note: These devices are designed to be used on individual outlets or appliances with flow rates of 0.25 L/s or less. ------------------------------------------------------------------------------------------------------------------------------
This Standard covers single check valve backflow preventers specifically designed for use in fire protection systems (SCVAF).