1.1 This practice covers the basic principles and operating procedures for using open flame carbon-arc light and water apparatus intended to reproduce the weathering effects that occur when materials are exposed to sunlight (either direct or through window glass) and moisture as rain or dew in actual use. This practice is limited to the procedures for obtaining, measuring, and controlling conditions of exposure. A number of exposure procedures are listed in an appendix; however, this practice does not specify the exposure conditions best suited for the material to be tested.

Note 1--Practice G151 describes performance criteria for all exposure devices that use laboratory light sources. This practice replaces Practice G23, which describes very specific designs for devices used for carbon-arc exposures. The apparatus described in Practice G23 is covered by this practice.

1.2 Test specimens are exposed to filtered open flame carbon arc light under controlled environmental conditions. Different filters are described.

1.3 Specimen preparation and evaluation of the results are covered in methods or specifications for specific materials. General guidance is given in Practice G151 and ISO 4892-1. More specific information about methods for determining the change in properties after exposure and reporting these results is described in ISO 4582.

1.4 The values stated in SI units are to be regarded as the standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.5.1 Should any ozone be generated from the operation of the light source, it shall be carried away from the test specimens and operating personnel by an exhaust system.

1.6 This practice is technically similar to ISO 4892-4.


SDO ASTM: ASTM International
Document Number G152
Publication Date Aug. 10, 2000
Language en - English
Page Count 7
Revision Level 00ae1
Supercedes
Committee G03.03
Publish Date Document Id Type View
July 1, 2013 G0152-13 Revision
March 15, 2006 G0152-06 Revision
Jan. 1, 2005 G0152-05 Revision
Sept. 10, 2004 G0152-04 Revision
Aug. 10, 2000 G0152-00AE01 Revision
Aug. 10, 2000 G0152-00A Revision
Aug. 10, 2000 G0152-00 Revision
June 1, 2021 G0152-13R21 Reaffirmation