ASTM F1877-05e1

Historical Revision

Standard Practice for Characterization of Particles

$91.00

$91.00

$163.80


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This practice covers a series of procedures for characterization of the morphology, number, size, and size distribution of particles. The methods utilized include sieves, optical, SEM, and electrooptical.

1.2 These methods are appropriate for particles produced by a number of different methods. These include wear test machines (Test Method F732), total joint simulation systems (Guides F1714 and F1715), abrasion testing, methods for producing particulates, such as shatter boxes or pulverizors, commercially available particles, and particles harvested from tissues in animal or clinical studies.

1.3 The debris may include metallic, polymeric, ceramic, or any combination of these.

1.4 The digestion procedures to be used and issues of sterilization of retrieved particles are not the subject of this practice.

1.5 A classification scheme for description of particle morphology is included in Appendix X3.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 As a precautionary measure, removed debris from implant tissues should be sterilized or minimally disinfected by an appropriate means that does not adversely affect the particulate material. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

The biological response to materials in the form of small particles, as from wear debris, often is significantly different from that to the same materials as larger implant components. The size and shape (morphology) of the particles may have a major effect on the biological response; therefore, this practice provides a standardized nomenclature for describing particles. Such a unified nomenclature will be of value in interpretation of biological tests of responses to particles, in that it will facilitate separation of biological responses associated with shape from those associated with the chemical composition of debris.

The quantity, size, and morphology of particles released as wear debris from implants in vivo may produce an adverse biological response which will affect the long term survival of the device. Characterization of such debris will provide valuable information regarding the effectiveness of device designs or methods of processing components and the mechanisms of wear.

The morphology of particles produced in laboratory tests of wear and abrasion often is affected by the test conditions, such as the magnitude and rate of load application, device configuration, and test environment. Comparison of the morphology and size of particles produced in vitro with those produced in vivo will provide valuable information regarding the degree to which the method simulates the in vivo condition being modeled.

SDO ASTM: ASTM International
Document Number F1877
Publication Date Nov. 1, 2005
Language en - English
Page Count 14
Revision Level 05e1
Supercedes
Committee F04.16
Publish Date Document Id Type View
Oct. 1, 2024 F1877-24 Revision
Oct. 1, 2016 F1877-16 Revision
Nov. 1, 2005 F1877-05E01 Revision
Nov. 1, 2005 F1877-05 Revision
April 10, 1998 F1877-98 Revision
June 1, 2010 F1877-05R10 Reaffirmation
April 10, 2003 F1877-98R03E01 Reaffirmation