Logo

ASTM F1807-14

Historical Revision

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring, or Alternate Stainless Steel Clamps, for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing

$83.00

$83.00

$149.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This specification covers metal insert fittings and copper crimp rings for use with cross-linked polyethylene (PEX) tubing in 3/8 , 1/2 , 5/8 , 3/4 , 1, 1 1/4 , 11/2 , and 2 in. nominal diameters that meet the requirements for Specification F876 and for use with polyethylene of raised temperature (PE-RT) tubing in 3/8 , 1/2 , 5/8 , 3/4 and 1 in. and 1 1/4 in. nominal diameters that meet the requirements of Specifications F2623 and F2769. These fittings are intended for use in 100 psi (689.5 kPa) cold- and hot-water distribution systems operating at temperatures up to, and including, 180°F (82°C). The requirements for materials, workmanship, dimensions, and markings to be used on the fittings and rings are also included.

1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units which are provided for information only and are not considered the standard.

1.3 Compliance with this specification requires that these fittings be tested and certified to Specification F877 when used with PEX tubing and Specification F2769 when used with PE-RT tubing.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


This specification covers metal insert fittings and copper crimp rings for use with SDR9 cross-linked polyethylene (PEX) tubing. All performance tests shall be performed on assemblies of fittings, crimp rings, and PEX tubing. Fittings and crimp rings shall meet the material and dimensional requirements prescribed. The sealing surfaces of the insert shall be smooth and free of foreign material. Fitting walls shall be free of cracks, holes, blisters, voids, foreign inclusions, or other defects that are visible to the unaided eye and affect the wall integrity. Insert fittings shall be joined to PEX tubing by the compression of a copper crimp ring around the outer circumference of the tubing, forcing the tubing material into annular spaces formed by ribs on the fitting.


SDO ASTM: ASTM International
Document Number F1807
Publication Date Aug. 1, 2014
Language en - English
Page Count 8
Revision Level 14
Supercedes
Committee F17.10
Publish Date Document Id Type View
Feb. 1, 2023 F1807-23 Revision
Nov. 1, 2019 F1807-19B Revision
Aug. 1, 2019 F1807-19A Revision
April 1, 2019 F1807-19 Revision
Nov. 1, 2018 F1807-18A Revision
Sept. 1, 2018 F1807-18 Revision
Feb. 1, 2017 F1807-17 Revision
April 1, 2015 F1807-15 Revision
Nov. 1, 2014 F1807-14A Revision
Aug. 1, 2014 F1807-14 Revision
Aug. 15, 2013 F1807-13A Revision
May 1, 2013 F1807-13 Revision
Aug. 1, 2012 F1807-12 Revision
June 1, 2011 F1807-11AE01 Revision
April 15, 2011 F1807-11 Revision
Feb. 1, 2010 F1807-10E01 Revision
Feb. 1, 2010 F1807-10 Revision
Dec. 1, 2009 F1807-09 Revision
March 1, 2008 F1807-08 Revision
Aug. 1, 2007 F1807-07AE01 Revision
Aug. 1, 2007 F1807-07A Revision
March 1, 2007 F1807-07 Revision
Nov. 15, 2005 F1807-05 Revision
April 1, 2004 F1807-04 Revision
Dec. 1, 2003 F1807-03 Revision
Oct. 10, 2002 F1807-02A Revision
May 10, 2002 F1807-02 Revision
April 10, 1999 F1807-99 Revision