1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits by the installation of a field-fabricated PVC liner. After installation of the liner, cementitious grout is injected into the annular space between the liner and the existing sewer or conduit. The rehabilitation of the host structure by this installation practice results in a rigid composite structure (PVC/grout/existing pipe). This rehabilitation process may be used in a variety of gravity applications, such as sanitary sewers, storm sewers and process piping of man-entry sizes (36 to 144 in. in vertical dimension). The profile strips used for field fabrication of PVC liners are supplied in coils for spiral winding of the liner or in custom-cut flat panels for circumferential lining of all or any portion of the circumference of the host conduit (see Figs. 1 and 2).

FIG. 1 Example of Profile PVC Strip


 Example of Profile PVC Strip Example of Profile PVC Strip

FIG. 2 Typical Installations with Panels

 Typical Installations with Panels Typical Installations with Panels

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


4.1 This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations involved in the rehabilitation of non-pressure sewers and conduits. As for any practice, modifications may be required for specific job conditions.

SDO ASTM: ASTM International
Document Number F1698
Publication Date July 1, 2021
Language en - English
Page Count 6
Revision Level 21
Supercedes
Committee F17.67
Publish Date Document Id Type View
July 1, 2021 F1698-21 Revision
March 1, 2015 F1698-02R15E01 Revision
Sept. 10, 2002 F1698-02 Revision
Jan. 1, 1996 F1698-96 Revision
March 1, 2015 F1698-02R15 Reaffirmation
March 1, 2008 F1698-02R08 Reaffirmation