1.1 This test method establishes a procedure for comparing the elemental composition of normal surfaces with any defects found on the surfaces of metal tubing, fittings, valves, or any metal component.

1.2 This test method applies to all steel surfaces of components such as tubing, connectors, regulators, and valves, regardless of size, style, or type.

1.3 Limitations:

1.3.1 This test method is intended for use by scanning electron microscope/energy dispersive x-ray spectrometer (SEM/EDX) operators with skill level typically achieved over a twelve-month period.

1.3.2 SEM used for this study should conform to those limitations outlined in Test Method F1372 and should have a minimum point-to-point resolution of 30 nm.

1.4 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.

1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 6.


SDO ASTM: ASTM International
Document Number F1375
Publication Date June 10, 1999
Language en - English
Page Count 4
Revision Level 92(1999)
Supercedes
Committee F01.10
Publish Date Document Id Type View
April 15, 2020 F1375-92R20 Revision
July 1, 2012 F1375-92R12 Reaffirmation
June 10, 1999 F1375-92R05 Reaffirmation
June 10, 1999 F1375-92R99 Reaffirmation