1.1 This test method covers the chemical analysis of copper having minimum purity of 99.75 % to 99.95 %.

1.2 This test method covers the electrolytic determination of copper in chemical, electrolytic, and fire refined copper. In this method silver is deposited with the copper, and is reported as copper.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 8.4 and Section 9.


5.1 This test method for the chemical analysis of copper is primarily intended to test for compliance with compositional specifications. It is assumed that all who use this method will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory.

SDO ASTM: ASTM International
Document Number E53
Publication Date Oct. 1, 2013
Language en - English
Page Count 4
Revision Level 07(2013)
Supercedes
Committee E01.05
Publish Date Document Id Type View
Oct. 1, 2013 E0053-07R13 Revision
Nov. 15, 2007 E0053-07 Revision
Dec. 10, 2002 E0053-02 Revision
Oct. 10, 1998 E0053-98 Revision