1.1 This practice describes the procedure for removing small quantities of ignitable liquid residues from samples of fire debris. An adsorbent material is used to extract the residue from the static headspace above the sample. Then, analytes are thermally desorbed in the injection port of the gas chromatograph (GC).

1.2 This practice is best suited for screening fire debris samples to assess relative ignitable liquid concentration and for extracting ignitable liquid from aqueous samples.

1.3 This practice is suitable for extracting ignitable liquid residues when a high level of sensitivity is required due to a very low concentration of ignitable liquid residues in the sample.

1.3.1 Unlike other methods of separation and concentration, this method recovers a minimal amount of the ignitable residues present in the evidence, leaving residues that are suitable for subsequent resampling.

1.4 Alternate separation and concentration procedures are listed in Section 2.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

This practice is suited ideally for screening samples for the presence, relative concentration, and potential class of ignitable liquid residues in fire debris.

This is a very sensitive separation procedure, capable of isolating small quantities of ignitable liquid residues from a sample, that is, a 0.1 μL spike of gasoline on a cellulose wipe inside of a 1-gal can is detectable.

Actual recovery will vary, depending on several factors, including adsorption temperature, container size, competition from the sample matrix, ignitable liquid class and relative ignitable liquid concentration.

Because this separation takes place in a closed container, the sample remains in approximately the same condition in which it was submitted. Repeat and interlaboratory analyses, therefore, may be possible. Since the extraction is nonexhaustive, the technique permits reanalysis of samples.

This practice is intended for use in conjunction with other extraction techniques described in Practices E 1385, E 1386, E 1388, E 1412, and E 1413.

The extract is consumed in the analysis. If a more permanent extract is desired, one of the separation practices described in Practices E 1385, E 1386, E 1412, or E 1413 should be used.

SDO ASTM: ASTM International
Document Number E2154
Publication Date Feb. 1, 2008
Language en - English
Page Count 3
Revision Level 01(2008)
Supercedes
Committee E30.01
Publish Date Document Id Type View
Sept. 1, 2015 E2154-15A Revision
March 1, 2015 E2154-15 Revision
Sept. 10, 2001 E2154-01 Revision
Feb. 1, 2008 E2154-01R08 Reaffirmation