1.1 This practice covers an ultrasonic extraction procedure for the extraction of lead from environmental samples of interest in lead abatement and renovation (or related) work, for analytical purposes.

1.2 Environmental matrices of concern include dry paint films, settled dusts, soils, and air particulates.

1.3 Samples subjected to ultrasonic extraction are prepared for subsequent determination of lead by laboratory analytical methods.

1.4 This practice includes, where applicable, descriptions of procedures for sample homogenization and weighing prior to ultrasonic extraction.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


5.1 Ultrasonic extraction using dilute nitric acid is a simpler and easier method for extracting lead from environmental samples than are traditional digestion methods that employ hot plate or microwave digestion with concentrated acids (3), (5), (7), (8). Hence, ultrasonic extraction may be used in lieu of the more rigorous strong acid/high temperature digestion methods (for example, see Ref (3) and Test Method E1613), provided that the performance is demonstrated using accepted criteria as delineated in Guide E1775.

5.2 In contrast with hot plate or microwave digestion techniques, ultrasonic extraction is field-portable, which allows for on-site sample analysis.

SDO ASTM: ASTM International
Document Number E1979
Publication Date Nov. 1, 2021
Language en - English
Page Count 7
Revision Level 21
Supercedes
Committee D22.12
Publish Date Document Id Type View
Nov. 1, 2021 E1979-21 Revision
March 1, 2017 E1979-17 Revision
July 15, 2012 E1979-12 Revision
Oct. 1, 2004 E1979-04 Revision
Sept. 10, 1998 E1979-98 Revision
Oct. 1, 2016 E1979-12R16 Reaffirmation