1.1 This specification covers a rigid wall, one-side expandable shelter constructed of aluminum-faced, nonmetallic honeycomb sandwich panels, and meeting the International Organization for Standardization (ISO) Cargo Container specification in the transport mode. Nominal dimensions when closed (container mode) are: height 8 ft, width 8 ft, and length 20 ft (2.4 by 2.4 by 6.1 m) Approximate dimensions, when expanded (shelter mode) are: height 8 ft, width 15 ft, and length 20 ft (2.4 by 4.6 by 6.1 m).

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 The following precautionary statement pertains to the test method portion only. Section 7, of this specification; This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determines the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


This specification covers a rigid wall, one-side expandable shelter constructed of aluminum-faced, nonmetallic honeycomb sandwich panels. Design and construction requirements of the expandable shelter shall conform to the requirements on the drawings, all subsidiary drawings and parts lists. Also, design and construction requirements for panels, inserts, payload, corner fittings, exterior lighting, and shelter electrical systems shall be met. The following test shall be conducted for each panel: electrical continuity test, water leakage test, performance test, paint adhesion test, packaging examination, thermal shock test, panel interchange test, insert proof load test, floor load test, roof load test, door load test, step test, airtightness test, low temperature test, high temperature test, humidity test, aging test, blackout test, panel watertightness test, insert working load test, rail transportability test, impact resistance test, drop test, towing test, fluorescent light temperature test, solar load test, operational test, lifting test, six high stacking test, longitudinal restraint test, racking test, lashing test, end wall strength test, sidewall strength test, lifting from fork lift pockets test, heat transfer test, panel delamination test, thickness test, and electrical system test.


SDO ASTM: ASTM International
Document Number E1977
Publication Date Sept. 1, 2018
Language en - English
Page Count 12
Revision Level 18
Supercedes
Committee E06.53
Publish Date Document Id Type View
July 1, 2024 E1977-24 Revision
Sept. 1, 2018 E1977-18 Revision
Sept. 1, 2011 E1977-11 Revision
May 1, 2005 E1977-05 Revision
April 1, 2004 E1977-04 Revision
April 10, 2001 E1977-98 Revision
April 10, 2001 E1977-01E01 Revision
April 10, 2001 E1977-01 Revision