ASTM E1106-12

Current Revision

Standard Test Method for Primary Calibration of Acoustic Emission Sensors

$91.00

$91.00

$163.80

$0.00

$0.00

$0.00



Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This test method covers the requirements for the absolute calibration of acoustic emission (AE) sensors. The calibration yields the frequency response of a transducer to waves, at a surface, of the type normally encountered in acoustic emission work. The transducer voltage response is determined at discrete frequency intervals of approximately 10 kHz up to 1 MHz. The input is a given well-established dynamic displacement normal to the mounting surface. The units of the calibration are output voltage per unit mechanical input (displacement, velocity, or acceleration).

1.2 UnitsThe values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Transfer StandardsOne purpose of this test method is for the direct calibration of displacement transducers for use as secondary standards for the calibration of AE sensors for use in nondestructive evaluation. For this purpose, the transfer standard should be high fidelity and very well behaved and understood. If this can be established, the stated accuracy should apply over the full frequency range up to 1 MHz.

Note 1—The stated accuracy applies only if the transfer standard returns to quiescence, following the transient input, before any wave reflected from the boundary of the calibration block returns to the transfer standard (100 μs). For low frequencies with periods on the order of the time window, this condition is problematical to prove.

Applications SensorsThis test method may also be used for the calibration of AE sensors for use in nondestructive evaluation. Some of these sensors are less well behaved than devices suitable for a transfer standard. The stated accuracy for such devices applies in the range of 100 kHz to 1 MHz and with less accuracy below 100 kHz.

SDO ASTM: ASTM International
Document Number E1106
Publication Date June 15, 2012
Language en - English
Page Count 12
Revision Level 12
Supercedes
Committee E07.04
Publish Date Document Id Type View
June 15, 2012 E1106-12 Revision
July 1, 2007 E1106-07 Revision
Jan. 1, 1992 E1106-86R92E01 Revision
June 1, 2021 E1106-12R21 Reaffirmation
June 1, 2017 E1106-12R17 Reaffirmation
Jan. 1, 1997 E1106-86R97 Reaffirmation
April 25, 1986 E1106-86R02E01 Reaffirmation