Historical Revision

Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves

$83.00

$83.00

$149.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This document specifies the technical requirements for; the woven wire test sieve cloth (sieve cloth) used in test sieves, the construction of test sieves, standard and non-standard test sieve frame sizes, and test procedures used to inspect sieve cloth and the test sieves. This Specification applies to test sieves manufactured with sieve cloth having a nominal aperture size ranging from 125 millimeters (mm) down to 20 micrometers (μm).

1.2 Additional reference information can be found in Specifications E 161, E 323, E 2016, and in Test Methods C 430 and E 2427.

1.3 The values stated in SI units shall be considered standard for the dimensions of the sieve cloth openings and the wire diameters used in the sieve cloth. The values stated in inch-pound units shall be considered standard with regard to the sieve frames, pans, and covers.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

The ASTM E11-09 Revision of the ASTM E 11 specification provides a complete ‘re-writing’ of the specification; aligning it more closely with ISO 3310. It covers the requirements for the sieve cloth itself, and for the design and construction of test sieves that use sieve cloth as a particle sizing medium to classify materials. This specification incorporates a maximum standard deviation value (where applicable) for the sieve cloth and for the Test Sieves. The maximum standard deviation values in Table 1 have been corrected by a K factor so as to increase the confidence level of the sieve cloth and the Test Sieve. (3) different confidence levels for Test Sieves are included - Compliance Test Sieves (66% confidence level), Inspection Test Sieves (99% confidence level), and Calibration Test Sieves (99.73% confidence level). Calibration Test Sieves have at least twice as many openings measured as Inspection Sieves. Similar to previous ASTM E 11 revisions, the specification covers the Test Sieve and its construction; standard frame sizes, non-standard frames, dimensional information, characteristics of the sieve frame, materials of construction for the sieve frame, attachment of the sieve cloth to the sieve frame, and specifies how test sieves should be labeled. Lastly, the specification Annex discusses in detail the proper procedure for inspection of the sieve cloth and the test sieve, to ensure that it complies with the requirements as shown in Table 1 of the specification.


SDO ASTM: ASTM International
Document Number E11
Publication Date May 1, 2009
Language en - English
Page Count 9
Revision Level 09e1
Supercedes
Committee E29.01
Publish Date Document Id Type View
Feb. 1, 2024 E0011-24 Revision
Feb. 1, 2022 E0011-22 Revision
April 1, 2020 E0011-20 Revision
April 1, 2017 E0011-17 Revision
Aug. 1, 2016 E0011-16 Revision
March 15, 2015 E0011-15 Revision
Oct. 1, 2013 E0011-13 Revision
May 1, 2009 E0011-09E01 Revision
May 1, 2009 E0011-09 Revision
May 1, 2004 E0011-04 Revision
May 10, 2001 E0011-95 Revision
May 10, 2001 E0011-01 Revision