1.1 Test Method A, Pressurization- This test method covers procedures for calibration of ultrasonic instruments, location, and estimated measurements of gas leakage to atmosphere by the airborn ultrasonic technique.

1.2 In general practice this should be limited to leaks producing leakage of 4.5 X 10 -7 m /s (10 atm[dot]cm /s at 0°C) or more. Refer to Guide E 432 for additional information.

1.3 Test Method B, Ultrasonic Transmitter- For object under test not capable of being pressurized but capable of having ultrasonic tone placed/injected into the test area to act as an ultrasonic leak trace source.

1.4The values stated in SI units are to be regarded as the standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


SDO ASTM: ASTM International
Document Number E1002
Publication Date Dec. 10, 1996
Language en - English
Page Count 4
Revision Level 96
Supercedes
Committee E07.08
Publish Date Document Id Type View
July 1, 2011 E1002-11 Revision
April 1, 2005 E1002-05 Revision
Dec. 10, 1996 E1002-96 Revision
June 1, 2022 E1002-11R22 Reaffirmation
June 1, 2018 E1002-11R18 Reaffirmation