1.1 This test method covers determination of nonylphenol (NP), nonylphenol ethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), octylphenol (OP), and bisphenol A (BPA) that are partitioned into organic solvent, separated using gas chromatography and detected with mass selective detection. These compounds or isomer mixtures are qualitatively and quantitatively determined by this method. This method adheres to selected ion monitoring mass spectrometry but full scan mass spectrometry has also been shown to work well under these conditions. Either analysis may be used.

1.2 The method detection limit (MDL) reporting limit (RL) for NP, NP1EO, NP2EO, OP, and BPA are listed in Table 1.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.


Nonylphenol, octylphenol, and bisphenol A have been shown to have toxic effects in aquatic organisms. The source of nonylphenol and octylphenol is prominently from the use of common commercial surfactants. The most widely used surfactant is NPEO which has an average ethoxylate chain of 9 mol of ethoxylate. The ethoxylate chain is readily biodegraded to form NP1EO and NP2EO, nonylphenol carboxylate (NPEC) and, under anaerobic conditions, nonylphenol. Nonylphenol will also biodegrade, but may be released into environmental waters directly at trace levels. This method has been investigated for use with surface water and waste treatment effluent samples and is applicable to these matrices. It has not been investigated for use with salt water or solid sample matrices.

SDO ASTM: ASTM International
Document Number D7065
Publication Date Dec. 15, 2006
Language en - English
Page Count 13
Revision Level 06
Supercedes
Committee D19.06
Publish Date Document Id Type View
Dec. 15, 2017 D7065-17 Revision
June 15, 2011 D7065-11 Revision
Dec. 15, 2006 D7065-06 Revision
April 1, 2024 D7065-17R24 Reaffirmation