1.1 This test method covers a procedure for the determination of the microbial condition (contamination or sterility) of raw materials used in the manufacture of paint, and the microbial condition of paint and paint manufacturing areas.

1.2 The values in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


3.1 Spoilage of paint in the container is often related to the use of contaminated raw materials, water (particularly recycled washwater), vessels, piping, and equipment in the manufacturing plant. There is a need for a simple method to determine the presence or absence of microorganisms in plants that manufacture paints and coatings. Such a determination enables the manufacturer to establish the point of contamination (that is, raw materials or problem housekeeping areas in the plant) to help in solving the spoilage problem.

Note 1: Some contamination in plant areas is to be expected, since microorganisms are ubiquitous and cannot generally be eliminated practically (it is what an in-can preservative is supposed to control). Excessive levels of contamination or contaminated raw materials can exceed the capability of the preservative. If you have excessive contamination in the plant, there are methods for decontamination including steam, preservatives, bleach, etc. These should be discussed with your biocide supplier and used with care. Recovery of spoiled or contaminated products is often not feasible, so an adequate level of the appropriate biocide in conjunction with good plant housekeeping practices are essential. Your biocide supplier can also help here.

3.2 This test method may be used by persons without basic microbiological training, but some training on aseptic techniques would be recommended.

Note 2: The reliability of the results obtained from this test method is extremely dependent on the techniques employed. Improper techniques can result in a sterile sample appearing to be contaminated, and even worse, a contaminated sample appearing to be sterile (see also 5.1). It is recommended that you consult with your biocide supplier, raw material supplier, or an independent testing laboratory to confirm questionable results.

SDO ASTM: ASTM International
Document Number D5588
Publication Date Nov. 1, 2021
Language en - English
Page Count 5
Revision Level 97(2021)
Supercedes
Committee D01.28
Publish Date Document Id Type View
July 10, 1997 D5588-97 Revision
Nov. 1, 2021 D5588-97R21 Reaffirmation
June 1, 2017 D5588-97R17 Reaffirmation
June 1, 2012 D5588-97R12 Reaffirmation
June 1, 2008 D5588-97R08 Reaffirmation