ASTM D5250-19

Current Revision

Standard Specification for Poly(vinyl chloride) Gloves for Medical Application

$73.00

$73.00

$131.40

$0.00

$0.00

$0.00



Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This specification covers certain requirements for poly(vinyl chloride) gloves used in conducting medical examinations and diagnostic and therapeutic procedures. It also covers poly(vinyl chloride) gloves used in handling contaminated medical material.

1.2 This specification provides for poly(vinyl chloride) gloves that fit either hand, paired gloves, and gloves by size. It also provides for packaged sterile or nonsterile or bulk nonsterile poly(vinyl chloride) gloves.

1.3 This specification does not cover two-dimensional heat sealed poly(vinyl chloride) gloves.

1.4 This specification is similar to that of Specification D3578 for rubber examination gloves.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


This specification contains procedures for evaluating the performance and safety of poly(vinyl chloride) gloves for use in conducting medical examinations, diagnostic and therapeutic procedures, and handling contaminated medical materials. The products covered by this specification include poly(vinyl chloride) gloves that fit either hand, paired gloves, and gloves by size and packaged sterile or nonsterile or bulk nonsterile. This specification does not include two-dimensional heat sealed poly(vinyl chloride) gloves. An approved lubricant for absorbable dusting powder may be applied to the gloves. Other lubricants may also be used, provided, that their safety and efficacy have been previously established. Both the inside and outside surface of the glove should be free of talc. All products should meet the required degree of sterility, freedom from holes, physical requirements before and after ageing, amount of powder on the glove, tensile strength and ultimate elongation.


4.1 The specification is intended as a referee procedure for evaluating the performance and safety of poly(vinyl chloride) examination gloves. The safe and proper use of poly(vinyl chloride) examination gloves is beyond the scope of this standard.

SDO ASTM: ASTM International
Document Number D5250
Publication Date Nov. 1, 2019
Language en - English
Page Count 4
Revision Level 19
Supercedes
Committee D11.40
Publish Date Document Id Type View
Nov. 1, 2019 D5250-19 Revision
Oct. 1, 2006 D5250-06E01 Revision
Oct. 1, 2006 D5250-06 Revision
Jan. 10, 2000 D5250-00E04 Revision
Jan. 10, 2000 D5250-00E03 Revision
Jan. 10, 2000 D5250-00E02 Revision
Jan. 10, 2000 D5250-00E01 Revision
Jan. 10, 2000 D5250-00 Revision
Sept. 1, 2023 D5250-19R23 Reaffirmation
Nov. 1, 2015 D5250-06R15 Reaffirmation
Nov. 1, 2011 D5250-06R11 Reaffirmation