Logo

ASTM D519-04(2013)

Current Revision

Standard Test Method for Length of Fiber in Wool Top (Withdrawn 2022)

$83.00

$83.00

$149.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This test method covers the measurement of the average length and length distribution of fibers in wool top, on a mass-biased basis. The method is applicable to all types of fibers in sliver formed from long parallelized fibers.

Note 1The determination of fiber length of wool is covered in Test Method D1575, Test Method for Fiber Length of Wool in Scoured Wool and in Card Sliver, the staple length of grease wool is covered in Test Method D1234, Test Method of Sampling and Testing Staple Length of Grease Wool.
Note 2This test method specifically requires length in inches and mass in SI units and is not contrary to ASTM policy. The SI units in parentheses are provided for information only.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


5.1 Knowledge of the average fiber length and the distribution of fibers is of primary importance to users of top in further processing.

5.2 Acceptance specifications for the fiber length and length distribution may be established by the user based on the type of yarn-making equipment employed and the desired end uses.

5.3 Test Method D519 for testing wool top for fiber length is considered satisfactory for acceptance testing of commercial shipments since the method has been used extensively in the trade for acceptance testing and the current estimates of the between-laboratory precisions are acceptable.

5.3.1 In case of a dispute arising from differences in reported test results when using this test method for acceptance testing of commercial shipments, the purchaser and the supplier should conduct comparative testing to determine if there is a statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. As a minimum, the two parties should take a group of test specimens that are as homogenous as possible and that are from a lot of the type material in question. The test specimens should then be assigned in equal numbers to each laboratory for testing. The average results from the two laboratories should be compared using Student's t-test for unpaired data and an acceptable probability level chosen by the two parties before testing is begun. If a bias is found either its cause must be found and corrected or the purchaser and supplier must agree to interpret future test results in the light of the known bias.

 Wool Fiber Stapling Apparatus

 

(Front View)

      (Rear View)

 

1—Frame.

      5—Drawing clamp.

 

2—Faller bars.

      6—Depressor.

 

3—Side comb.

      7—Plush board.

 

4—Retaining bars.

      8—Faller bar lifting plate.


FIG. 1 Wool Fiber Stapling Apparatus
TABLE 1 Form with Recorded Data Showing the Calculation of the Average Fiber Length of Wool, the Standard Deviation, and Coefficient of Variation
Note 1When using equipment graduated in metric units, use class intervals 10 mm long, and calculate the average and standard deviation to the nearest 0.2 mm.

Class Intervals, in.

Mass, g

Percentages

Cumulative Frequencies

First Cumulative,
less than

Second Cumulative,
less than

6.0 to 6.5

0.014

  2.4

100.0

 840.1

5.5 to 6.0

0.010

  1.7

 97.6

 740.1

5.0 to 5.5

0.013

  2.2

 95.9

 642.5

4.5 to 5.0

0.018

  3.1

 93.7

 546.6

4.0 to 4.5

0.038

  6.5

 90.6

 452.9

3.5 to 4.0

0.051

  8.7

 84.1

 362.3

3.0 to 3.5

0.062

 10.6

 75.4

 278.2

2.5 to 3.0

0.072

 12.3

 64.8

 202.8

2.0 to 2.5

0.079

 13.5

 52.5

 138.0

1.5 to 2.0

0.080

 13.6

 39.0

  85.5

1.0 to 1.5

0.065

 11.0

 25.4

  46.5

0.5 to 1.0

0.045

  7.7

 14.4

  21.1

  0 to 0.5

0.039

  6.7

  6.7

   6.7

 

 

 

 

 

 

  

  

  

  

Totals

0.586

100.0 = 

840.1

4363.3

 

Divided by percentages

F 1 = 8.40

F 2 = 43.63


B = the largest midpoint value for which a frequency is recorded = 6.25 in.

m = the class interval = 0.5 in.

Percentage of fibers under 2 in. = 39.0 %.

Calculations:

Equation D0519-04R13_1

Equation D0519-04R13_2

v = 100 (σ/X) = 100 × (1.4/2.6) = 56.47 %.

where:
X   =   average fiber length of wool,
s   =   standard deviation, and
v   =   coefficient of variation.

SDO ASTM: ASTM International
Document Number D519
Publication Date July 1, 2013
Language en - English
Page Count 5
Revision Level 04(2013)
Supercedes
Committee D13.13
Publish Date Document Id Type View
July 1, 2013 D0519-04R13 Revision
March 1, 2004 D0519-04 Revision
Aug. 1, 2008 D0519-04R08 Reaffirmation
Jan. 1, 2001 D0519-90R01 Reaffirmation
Jan. 1, 2001 D0519-90R95E01 Reaffirmation