1.1 This test method describes the sampling and continuous analysis of ozone (O3) in the atmosphere at concentrations ranging from 10 to 2000 μg/m3 of O3 in air (5 ppb(v) to 1 ppm(v)).

1.1.1 The test method is limited to applications by its sensitivity to interferences as described in Section 6. The interference sensitivities may limit its use for ambient and workplace atmospheres.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


5.1 Standards for O3 in the atmosphere have been promulgated by government authorities to protect the health and welfare of the public (6) and also for the protection of industrial workers (7).

5.2 Although O3 itself is a toxic material, in ambient air it is primarily the photochemical oxidants formed along with O3 in polluted air exposed to sunlight that cause smog symptoms such as lachrymation and burning eyes. Ozone is much more easily monitored than these photochemical oxidants and provides a good indication of their concentrations, and it is therefore the substance that is specified in air quality standards and regulations.

SDO ASTM: ASTM International
Document Number D5156
Publication Date Sept. 1, 2022
Language en - English
Page Count 7
Revision Level 22
Supercedes
Committee D22.03.02
Publish Date Document Id Type View
Sept. 1, 2022 D5156-22 Revision
Oct. 10, 2002 D5156-02 Revision
Jan. 1, 1995 D5156-95 Revision
Oct. 1, 2016 D5156-02R16 Reaffirmation
April 1, 2008 D5156-02R08 Reaffirmation