1.1 This test method covers the measurement of radon in drinking water in concentrations above 2 Bq/L.

1.2 This test method may be used for absolute measurements by calibrating with a 226Ra standard or for relative measurements by comparing the measurements made with each other.

1.3 This test method is used successfully with drinking water samples and Type III reagent water conforming to Specification D1193. It is the user’s responsibility to ensure the validity of this test method for waters of untested matrices.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


5.1 The most prevalent of the radon isotopes in ground water is 222Rn. This isotope presents the greatest health risk compared to the other naturally occurring radon isotopes if ingested via the water pathway.

SDO ASTM: ASTM International
Document Number D5072
Publication Date Feb. 1, 2016
Language en - English
Page Count 6
Revision Level 09(2016)
Supercedes
Committee D19.04
Publish Date Document Id Type View
Feb. 1, 2009 D5072-09E01 Revision
Feb. 1, 2009 D5072-09 Revision
April 10, 1998 D5072-98 Revision
Nov. 1, 2024 D5072-09R24 Reaffirmation
Feb. 1, 2016 D5072-09R16 Reaffirmation