1.1 This test method provides details for the determination of respirable dust concentration defined in terms of international convention in a range from 0.5 to 10 mg/m3 in workplace atmospheres. Specifics are given for sampling and analysis using any one of a number of commercially available cyclone samplers.

1.2 The limitations on the test method are a minimum weight of 0.1 mg of dust on the filter, and a maximum loading of 0.3 mg/m2 on the filter. The test method may be used at higher loadings if the flow rate can be maintained constant.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This test method contains notes that are explanatory and are not part of the mandatory requirements of the method.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


5.1 This test method covers the determination of respirable dust concentration in workplace atmospheres.

5.2 Variations of the test method are in world-wide use for determining compliance relative to occupational exposure levels.

5.3 The test method may be used to verify dust control measures.

5.4 The test method may also be applied in research into health effects of dust in an occupational setting.

SDO ASTM: ASTM International
Document Number D4532
Publication Date Oct. 1, 2015
Language en - English
Page Count 6
Revision Level 15
Supercedes
Committee D22.04
Publish Date Document Id Type View
Nov. 15, 2022 D4532-22 Revision
Oct. 1, 2015 D4532-15 Revision
April 1, 2010 D4532-10 Revision
Dec. 10, 1997 D4532-97 Revision
April 10, 2003 D4532-97R03 Reaffirmation