Logo

ASTM D4292-23

Current Revision

Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke

$69.00

$69.00

$124.20

$83.00

$83.00

$149.40



Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This test method covers the determination of bulk density of a representative 2 kg sample of calcined petroleum coke, after vibration to increase compaction.

1.2 The procedure is limited to particles passing through a 6.68 mm opening sieve (equivalent to a 0.265 in. USA Series) and retained on a 0.21 mm opening sieve (equivalent to a 70 mesh USA Series). Further, the procedure is limited to a specific test sample having particles retained between screens having openings that differ by a factor of less than Equation D4292-23_1 and preferably less than 2.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


5.1 Vibrated bulk density, VBD, is an indicator of calcined petroleum coke porosity, which affects its suitability for use in pitch-bonded carbon applications. (Warning—Vibrated bulk density for a sample of calcined petroleum coke is strongly dependent upon average particle size and particle size range. Bulk density tends to increase with decreasing coke size. A narrow particle size range for this test minimizes the possibility for variation due to skewing of the test sample toward either screen defining the sample. Particle size range tested should be agreed upon by the purchaser and supplier.)

Note 1: An example of the use of VBD to characterize coke for prebaked anodes for aluminum smelting is reported by Belitskus3 who found particles passing through a 0.59 mm opening, No. 30, sieve and retained on a 0.30 mm opening, No. 50, sieve to be preferred. Other popular ranges are particles passing through a 2.36 mm opening, No. 8, sieve and retained on a 1.17 mm opening, No. 16, sieve for the continuous Soderberg anode process and particles passing through a 6.68 mm opening sieve (equivalent to a 0.265 in. USA Series) and retained on a 3.33 mm opening, No. 6, sieve for graphite electrode manufacture.

SDO ASTM: ASTM International
Document Number D4292
Publication Date Nov. 1, 2023
Language en - English
Page Count 5
Revision Level 23
Supercedes
Committee D02.05
Publish Date Document Id Type View
Nov. 1, 2023 D4292-23 Revision
Dec. 1, 2017 D4292-17 Revision
July 1, 2010 D4292-10 Revision
May 1, 2007 D4292-92R07 Reaffirmation
Nov. 10, 1997 D4292-92R02E01 Reaffirmation
Nov. 10, 1997 D4292-92R97 Reaffirmation