Logo

ASTM D4248-98

Historical Revision

Standard Practice for Design of Steam Turbine Generator Oil Systems

$73.00

$73.00

$131.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


...

1.1 This practice is applicable to steam turbine-generator units and provides recommended practices for the design of the oil system.

1.1.1 The oil system is defined as that assembly which uses and circulates the turbine-generator lubricating oil. The oil system generally includes high pressure, bearing, control, generator seal, and drain systems. The system may also include the supply and return lines for a boiler feed pump and hydraulic coupling.

1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


SDO ASTM: ASTM International
Document Number D4248
Publication Date June 10, 1998
Language en - English
Page Count 3
Revision Level 98
Supercedes
Committee D02.C0.01
Publish Date Document Id Type View
Nov. 1, 2003 D4248-98R03 Revision
June 10, 1998 D4248-98 Revision