1.1 This practice covers the collection, dissolution, and determination of trace metals in workplace atmospheres, by flame atomic absorption spectrophotometry.

1.2 The sensitivity, detection limit, and optimum working concentration for 23 metals are given in Table 1.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Specific safety precautionary statements are given in Section 9.)

TABLE 1 AAS Instrumental Detection Limits and Optimum Working Concentration for 23 Metals

ElementDetection Limit, μg/mL
(approximately three times
standard deviation of blank)A
Optimum Linear Range
Upper Limit,
μg/mL
TLV, mg/m3 (elements, compound classes, and oxides)B
Ag0.00150.1 (metal) 0.01 (soluble compounds as Ag)
Al0.04502.0 (soluble salts and alkyls not otherwise classified) 10 (metal dust and oxide)
5 (pyro powder and welding fume)
Ba0.01100.5 (soluble compounds)
Bi0.0310No Limit expressed for this element
Ca0.00212 (oxide as CaO)
Cd0.000810.01 (elemental and compoundstotal dust)
0.002 (elemental compoundsrespirable fraction)
Co0.00950.02 (elemental and inorganic) 0.1 (carbonyl and hydrocarbonyl)
Cr0.00350.5 (metal and Cr III compounds) 0.05 (water soluble Cr VI compounds)
0.01 (insoluble Cr VI compounds)
Cu0.00250.2 (fume) 1 (dust and mists as Cu)
Fe0.00555 (iron oxide fume) 5 (soluble salts as Fe)
In0.03500.1 (metal and compounds)
K0.0031No Limit expressed for this element
Li0.00081No Limit expressed for this element
Mg0.00020.510 (as MgO fume)
Mn0.00250.2 (elemental and inorganic compounds)
Na0.00030.5No Limit expressed for this element
Ni0.00650.05 (elemental, soluble and insoluble compounds)
Pb0.02100.15 (inorganic compounds, fume, dust)
Rb0.0035No Limit expressed for this element
Sr0.0035No Limit expressed for this element
Tl0.02500.1 (soluble compounds)
V0.061000.05 (pentoxide, respirable dust or fume, as V2O5)
Zn0.002110 (oxide dust as ZnO) 5 (oxide fume as ZnO)

A These detection limits represent ideal laboratory conditions; variability due to sampling, digestion, reagents, and sample handling has not been taken into account.

B Threshold Limit Values of Airborne Contaminants and Physical Agents adopted by ACGIH for 19941995. Values are elemental concentrations except as noted.


The health of workers in many industries is at risk through exposure by inhalation to toxic metals. Industrial hygienists and other public health professionals need to determine the effectiveness of measures taken to control workers' exposures, and this is generally achieved by making workplace air measurements. Exposure to some metal-containing particles has been demonstrated to cause dermatitis, skin ulcers, eye problems, chemical pneumonitis, and other physical disorders (1).

AAS is capable of quantitatively determining most metals in air samples at the levels required by federal, state, and local occupational health and air pollution regulations. The analysis results can be used for the assessment of workplace exposures to metals in workplace air.

SDO ASTM: ASTM International
Document Number D4185
Publication Date Oct. 1, 2011
Language en - English
Page Count 7
Revision Level 06(2011)
Supercedes
Committee D22.04
Publish Date Document Id Type View
Sept. 1, 2023 D4185-23 Revision
March 1, 2017 D4185-17 Revision
Oct. 1, 2006 D4185-06 Revision
Oct. 10, 1996 D4185-96 Revision
Oct. 1, 2011 D4185-06R11 Reaffirmation
Oct. 10, 1996 D4185-96R01E01 Reaffirmation