1.1 This specification covers machine-made fiberglass pipe, 8 in. (200 mm) through 156 in. (4000 mm), for use in pressure systems for conveying sanitary sewage, storm water, and many industrial wastes, and corrosive fluids. Both glass-fiber-reinforced thermosetting-resin pipe (RTRP) and glass-fiber-reinforced polymer mortar pipe (RPMP) are fiberglass pipes. This standard is suited primarily for pipes to be installed in buried applications, although it may be used to the extent applicable for other installations such as, but not limited to, jacking, tunnel lining and slip-lining and rehabilitation of existing pipelines. Pipe covered by this specification is intended to operate at internal gage pressures of 450 psi (3103 kPa) or less.

Note 1—For the purposes of this standard, polymer does not include natural polymers.

1.2 The values given in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.

Note 2—There is no similar or equivalent ISO standard.

1.3 The following precautionary caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


This specification covers machine-made fiberglass pipe for use in pressure systems for conveying sanitary sewage, storm water, and many industrial wastes, and corrosive fluids. Both glass-fiberreinforced thermosetting-resin pipe (RTRP) and glass-fiberreinforced polymer mortar pipe (RPMP) are fiberglass pipes. This standard is suited primarily for pipes to be installed in buried applications, although it may be used to the extent applicable for other installations such as, but not limited to, jacking, tunnel lining and slip-lining and rehabilitation of existing pipelines. The pipe is intended to operate at certain internal gage pressures. The fiberglass sewer and industrial pressure pipe are defined by raw materials in the structural wall (type) and liner, surface layer material (grade), operating pressure (class), and pipe stiffness. Different tests shall be performed in order to determine the following properties of pipe: inside diameter, outside diameter, length, wall thickness, squareness of pipe ends, chemical resistance, soundness, stiffness, hoop-tensile strength, beam strength, longitudinal tensile strength, and longitudinal compressive strength.


SDO ASTM: ASTM International
Document Number D3754
Publication Date Nov. 1, 2006
Language en - English
Page Count 14
Revision Level 06
Supercedes
Committee D20.23
Publish Date Document Id Type View
Aug. 1, 2024 D3754-24 Revision
Nov. 1, 2019 D3754-19 Revision
March 1, 2014 D3754-14 Revision
Sept. 1, 2011 D3754-11 Revision
Nov. 1, 2006 D3754-06 Revision
April 1, 2004 D3754-04 Revision
May 10, 2003 D3754-03 Revision
June 10, 2001 D3754-96 Revision
June 10, 2001 D3754-01 Revision