Logo

ASTM D2862-97

Historical Revision

Standard Test Method for Particle Size Distribution of Granular Activated Carbon

$73.00

$73.00

$131.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This test method covers the determination of the particle size distribution of granular activated carbon. For purposes of this test, granular activated carbon is defined as a minimum of 90% retained on a 180-[mu]m Standard sieve.

Note 1-For extruded carbons, as the length/diameter ratio of the particles increases, the validity of the test results might be affected.

1.2 The data obtained may also be used to calculate mean particle diameter (MPD), effective size, and uniformity coefficient.

1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


SDO ASTM: ASTM International
Document Number D2862
Publication Date Dec. 10, 1997
Language en - English
Page Count 4
Revision Level 97
Supercedes
Committee D28.04
Publish Date Document Id Type View
June 1, 2016 D2862-16 Revision
April 1, 2010 D2862-10 Revision
Sept. 1, 2009 D2862-97R09E01 Revision
Dec. 10, 1997 D2862-97 Revision
Sept. 1, 2022 D2862-16R22 Reaffirmation
Sept. 1, 2009 D2862-97R09 Reaffirmation
April 1, 2004 D2862-97R04 Reaffirmation