Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This specification covers poly(vinyl chloride) (PVC) pipe made in Schedule 40, 80, and 120 sizes and pressure-rated for water (see Appendix). Included are criteria for classifying PVC plastic pipe materials and PVC plastic pipe, a system of nomenclature for PVC plastic pipe, and requirements and test methods for materials, workmanship, dimensions, sustained pressure, burst pressure, flattening, and extrusion quality. Methods of marking are also given.

1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.

1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 The following safety hazards caveat pertains only to the test methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in Note 7.

Note 1-CPVC plastic pipes, Schedules 40 and 80, which were formerly included in this specification, are now covered by Specification F441. Note 2-The sustained and burst pressure test requirements, and the pressure ratings in the Appendix, are calculated from stress values obtained from tests made on pipe 4 in. (100 mm) and smaller. However, tests conducted on pipe as large as 24-in. (600-mm) diameter have shown these stress values to be valid for larger diameter PVC pipe. Note 3-PVC pipe made to this specification is often belled for use as line pipe. For details of the solvent cement bell, see Specification D2672 and for details of belled elastomeric joints, see Specifications D3139 and D3212.

SDO ASTM: ASTM International
Document Number D1785
Publication Date May 10, 1999
Language en - English
Page Count 11
Revision Level 99
Supercedes
Committee F17.25
Publish Date Document Id Type View
Aug. 1, 2021 D1785-21A Revision
May 1, 2021 D1785-21 Revision
Aug. 1, 2015 D1785-15E01 Revision
Aug. 1, 2015 D1785-15 Revision
April 1, 2012 D1785-12 Revision
May 1, 2006 D1785-06 Revision
Aug. 1, 2005 D1785-05 Revision
Sept. 1, 2004 D1785-04A Revision
May 1, 2004 D1785-04 Revision
May 10, 2003 D1785-03 Revision
May 10, 1999 D1785-99 Revision