1.1 This practice covers the repair of spray-applied polyurethane insulation on vessels normally operating at temperatures between −30 and +107°C [−22 and +225°F].

1.2 Warning—At temperatures below 0°C [32°F] the application of a spray “foam” directly onto the cold substrate may not be possible. The term “foam” applies to spray-applied polyurethane or polyisocyanurate (PUR or PIR) rigid cellular plastic only, and not to any other plastic insulation.

1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement see 1.2.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


This practice covers the repair of rigid cellular polyurethane insulation systems on outdoor service vessels operating within a specified temperature range. Before any repairs are performed, all damaged nonadhering foam should be removed up to the dry, solidly adhering layer and the remaining foam insulation should then be beveled on all sides. If the existing substrate primer is damaged, it should be wire-brushed and reprimed where feasible. To protect the surrounding undamaged area, a covering should be installed around the area that needs to be repaired prior to the application of spray foam. Repairs shall be made in accordance with the prescribed procedure.


SDO ASTM: ASTM International
Document Number C950
Publication Date March 1, 2023
Language en - English
Page Count 2
Revision Level 08(2023)
Supercedes
Committee C16.40
Publish Date Document Id Type View
Dec. 1, 2008 C0950_C0950M-08 Revision
March 1, 2023 C0950_C0950M-08R23 Reaffirmation
Sept. 1, 2017 C0950_C0950M-08R17 Reaffirmation
Oct. 1, 2012 C0950_C0950M-08R12 Reaffirmation