1.1 This specification pertains to blended hydraulic cements for both general and special applications, using slag, pozzolan, limestone, or some combination of these, with portland cement or portland cement clinker or slag with lime.

Note 1: This specification prescribes ingredients and proportions, with some performance requirements, whereas Performance Specification C1157 is a hydraulic cement specification in which performance criteria alone govern the products and their acceptance.

1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Values in SI units [or inch-pound units] shall be obtained by measurement in SI units [or inch-pound units] or by appropriate conversion, using the Rules for Conversion and Rounding given in IEEE/ASTM SI 10, of measurements made in other units [or SI units]. Values are stated in only SI units when inch-pound units are not used in practice.

1.3 The text of this standard refers to notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) are not requirements of the standard.


This specification pertains to blended hydraulic cements for both general and special applications, using slag or pozzolan, or both, with portland cement or portland cement clinker or slag with lime. These cements are classified into two types: Type IS which is portland blast-furnace slag cement and Type IP which is portland-pozzolan cement. They can also be described according to air-entraining, moderate sulfate resistance, moderate heat of hydration, high sulfate resistance, or low heat of hydration properties. The cement shall conform to the chemical requirements prescribed. In addition, the cement shall undergo different tests to determine the following properties: chemical analysis, fineness by sieving, fineness by air-permeability, autoclave expansion, time of setting, air content of mortar, compressive strength, heat of hydration, normal consistency, specific gravity, water requirement, mortar expansions of blended cement and pozzolan, drying shrinkage, activity index with Portland cement, and sulfate resistance.


SDO ASTM: ASTM International
Document Number C595
Publication Date March 15, 2016
Language en - English
Page Count 8
Revision Level 16
Supercedes
Committee C01.10
Publish Date Document Id Type View
July 1, 2024 C0595_C0595M-24 Revision
July 15, 2023 C0595_C0595M-23 Revision
July 15, 2021 C0595_C0595M-21 Revision
April 1, 2020 C0595_C0595M-20 Revision
April 1, 2019 C0595_C0595M-19 Revision
April 1, 2018 C0595_C0595M-18 Revision
April 1, 2017 C0595_C0595M-17 Revision
March 15, 2016 C0595_C0595M-16 Revision
July 1, 2015 C0595_C0595M-15E01 Revision
July 1, 2015 C0595_C0595M-15 Revision
May 1, 2014 C0595_C0595M-14 Revision
March 1, 2013 C0595_C0595M-13 Revision
July 18, 2012 C0595_C0595M-12E01 Revision
May 1, 2012 C0595_C0595M-12 Revision
April 1, 2011 C0595_C0595M-11 Revision
April 1, 2010 C0595_C0595M-10 Revision
June 15, 2009 C0595_C0595M-09 Revision