1.1 This specification covers the composition, sizes, dimensions, and physical properties of cellular glass thermal insulation intended for use on commercial or industrial systems with operating temperatures between −450 and 800°F (−268 and 427°C). It is possible that special fabrication or techniques for pipe insulation, or both, will be required for application in the temperature range from 250 to 800°F (121 to 427°C). Contact the manufacturer for recommendations regarding fabrication and application procedures for use in this temperature range. For specific applications, the actual temperature limits shall be agreed upon between the manufacturer and the purchaser.

1.2 This specification does not cover cellular glass insulation used for building envelope applications. For cellular glass insulation used in building applications refer to Specification C1902.

1.3 Cellular glass insulation has the potential to exhibit stress cracks if the rate of temperature change exceeds 200°F (112°C) per hour.

1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


This specification covers the composition, sizes, dimensions, and physical properties of cellular glass thermal insulation. The material shall consist of a glass composition that has been foamed or cellulated under molten conditions, annealed, and set to form a rigid noncombustible material with hermetically sealed cells. The materials shall also be trimmed into rectangular or tapered blocks of standard dimensions. All specimens shall also comply with with qualification requirements such as compressive strength, flexural strength, water absorption, water vapor permeability, thermal conductivity, hot-surface performance, thermal conductivity and surface burning characteristics. These properties shall be determined in accordance with test methods specified herein.


SDO ASTM: ASTM International
Document Number C552
Publication Date March 1, 2022
Language en - English
Page Count 6
Revision Level 22
Supercedes
Committee C16.20
Publish Date Document Id Type View
March 1, 2022 C0552-22 Revision
Sept. 1, 2021 C0552-21A Revision
March 1, 2021 C0552-21 Revision
Oct. 1, 2017 C0552-17E01 Revision
Oct. 1, 2017 C0552-17 Revision
Sept. 1, 2016 C0552-16A Revision
March 1, 2016 C0552-16 Revision
May 1, 2015 C0552-15 Revision
Sept. 1, 2014 C0552-14 Revision
Sept. 1, 2013 C0552-13 Revision
Oct. 1, 2012 C0552-12B Revision
Sept. 15, 2012 C0552-12A Revision
May 1, 2012 C0552-12 Revision
Dec. 1, 2007 C0552-07 Revision
Nov. 1, 2003 C0552-03 Revision
Jan. 10, 2000 C0552-00E01 Revision
Jan. 10, 2000 C0552-00 Revision
Not Available C0552-88 Revision