Logo

ASTM C506-08a

Historical Revision

Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe

$83.00

$83.00

$149.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.

1.2 This specification is the inch-pound companion to C 506M; therefore, no SI equivalents are presented in the specification.

Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.


This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. The aggregate shall be so sized, graded, proportioned, and mixed with such proportions of Portland cement, blended hydraulic cement, or Portland cement and supplementary cementing materials, or admixtures, or a combination thereof, if used, and water to produce a homogeneous concrete mixture of such quality that the pipe will conform to the test and design requirement. The combination of cementitious materials used in the concrete shall be one of the following: Portland cement only, Portland blast furnace slag cement only, slag modified Portland cement only, Portland pozzolan cement only, a combination of Portland cement and ground- granulated blast-furnace slag, a combination of Portland cement and fly ash or a combination of Portland cement, ground granulated blast-furnace slag and fly ash. The materials shall undergo external load crushing strength test, compression test and absorption test. They shall also conform to the required internal dimensions, wall thickness, length of two opposite sides, length of pipe, position or area of reinforcement.


SDO ASTM: ASTM International
Document Number C506
Publication Date April 15, 2008
Language en - English
Page Count 7
Revision Level 08a
Supercedes
Committee C13.02
Publish Date Document Id Type View
Sept. 15, 2022 C0506-22A Revision
Sept. 1, 2022 C0506-22 Revision
Sept. 1, 2020 C0506-20E01 Revision
Sept. 1, 2020 C0506-20 Revision
July 15, 2019 C0506-19A Revision
July 1, 2019 C0506-19 Revision
Oct. 1, 2018 C0506-18 Revision
Nov. 1, 2016 C0506-16B Revision
March 1, 2016 C0506-16A Revision
Jan. 1, 2016 C0506-16 Revision
Jan. 1, 2015 C0506-15 Revision
May 1, 2014 C0506-14 Revision
Feb. 15, 2013 C0506-13A Revision
Jan. 15, 2013 C0506-13 Revision
Sept. 15, 2012 C0506-12A Revision
May 1, 2012 C0506-12 Revision
Feb. 1, 2011 C0506-11 Revision
Oct. 1, 2010 C0506-10B Revision
April 1, 2010 C0506-10A Revision
Feb. 1, 2010 C0506-10 Revision
June 1, 2009 C0506-09 Revision
April 15, 2008 C0506-08A Revision
Jan. 15, 2008 C0506-08 Revision
March 15, 2007 C0506-07 Revision
May 15, 2005 C0506-05A Revision
Feb. 1, 2005 C0506-05 Revision
July 10, 2002 C0506-02 Revision
May 10, 2000 C0506-00 Revision