1.1 This specification applies to the minimum installation requirements for non metallic plaster bases used with portland cement based plaster in vertical wall applications.

1.2 Where a fire resistance rating is required for plastered assemblies and constructions, details of construction shall be in accordance with reports of fire tests of assemblies that have met the requirements of the fire rating imposed.

1.3 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.4 Details of construction for a specific assembly to achieve the required fire resistance, sound or acoustic rating shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing, sound or acoustic laboratories.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


This specification describes the minimum requirements for the installation of non-metallic plaster bases used with portland cement-based plaster in vertical wall applications. In cases where a fire resistance rating is required for plastered assemblies and constructions, the construction details shall conform to reports of fire tests of assemblies that have satisfied the requirements of the fire rating imposed. The standard defines the requirements with respect to delivery and storage of materials, coordination and scheduling of installation, application of accessories, and application of non-metallic plaster bases.


SDO ASTM: ASTM International
Document Number C1787
Publication Date Feb. 1, 2014
Language en - English
Page Count 2
Revision Level 14
Supercedes
Committee C11.03
Publish Date Document Id Type View
July 1, 2023 C1787-23 Revision
Oct. 1, 2020 C1787-20 Revision
Feb. 1, 2014 C1787-14 Revision
March 1, 2019 C1787-14R19 Reaffirmation