1.1 This specification covers stainless steel jacketing for thermal, acoustical, and fire protective insulation operating at either above or below ambient temperatures and in both indoor and outdoor locations. It does not cover insulation jacketing made from other materials such as mastics, fiber reinforced plastic, PVC, aluminum, or coated carbon steel (for example, aluminum-zinc, galvanized steel, or aluminized steel) nor does it cover the details of thermal, acoustical, or fire protective insulation systems.

1.2 While not intended to cover use inside the containment buildings of nuclear power plants, this standard does not preclude use of Class E material which does not have a moisture barrier in this containment building application.

1.3 This specification provides physical requirements for stainless steel jacketing for thermal and acoustical insulation. Guide C1423 provides guidance in selecting jacketing materials and their safe use.

1.4 This is a material specification and does not imply any performance of the installed system using the materials specified herein. For information about installation of stainless steel jacketing, see (1).2

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

Note 1: A version of this specification in IP units is available as Specification C1767.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


This specification applies to stainless steel jacketing for thermal, acoustical, and fire protective insulation operating at either above or below ambient temperatures and in both indoor and outdoor locations. It provides physical requirements for stainless steel jacketing for thermal and acoustical insulation, but does not cover insulation jacketing made from other materials such as mastics, fiber reinforced plastic, PVC, aluminum, or coated carbon steel (for example, aluminum-zinc, galvanized steel, or aluminized steel). This specification also covers the classification of stainless steel jacketing, stainless steel jacketing materials and manufacture, required physical properties, workmanship, finish and appearance, sampling, inspection, certification, product marking, and packaging.


SDO ASTM: ASTM International
Document Number C1767
Publication Date Sept. 1, 2016
Language en - English
Page Count 7
Revision Level 16a
Supercedes
Committee C16.40
Publish Date Document Id Type View
March 1, 2021 C1767M-21 Revision
Sept. 1, 2019 C1767M-19 Revision
Sept. 1, 2016 C1767M-16A Revision
March 1, 2016 C1767M-16 Revision
Nov. 1, 2015 C1767M-15 Revision
Oct. 1, 2014 C1767M-14 Revision