Logo

ASTM C118-05a

Historical Revision

Standard Specification for Concrete Pipe for Irrigation or Drainage

$73.00

$73.00

$131.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1 and for use in drainage.

1.2 A complete SI companion to Specification C 118 has been developed—C 118M; therefore, no SI equivalents are presented in this specification.

Note 1R`12;This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.


This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients and for use in drainage. The concrete shall consist of cementitious materials, minerals, aggregates, and water. Cement shall conform to the requirements for Portland cement or shall be Portland blast-furnace slag cement, or slag modified Portland cement, or Portland-pozzolan cement conforming to the requirements except that the pozzolan constituent in the Type IP Portland-pozzolan cement shall be fly ash. The combination of cementitious materials used in the concrete shall be one of the following: Portland cement only, Portland blast furnace slag cement only, slag modified portland cement only, portland pozzolan cement only, a combination of Portland cement and fly ash, a combination of portland cement and ground-granulated blast-furnace slag or a combination of fly ash and ground granulated blast furnace slag. The specimens shall undergo external load test, absorption test and hydrostatic test. The material shall also conform to the required internal diameter and wall thickness.


SDO ASTM: ASTM International
Document Number C118
Publication Date Dec. 1, 2005
Language en - English
Page Count 4
Revision Level 05a
Supercedes
Committee C13.01
Publish Date Document Id Type View
July 15, 2019 C0118-19 Revision
Oct. 1, 2015 C0118-15 Revision
Sept. 1, 2011 C0118-11 Revision
Dec. 1, 2005 C0118-05A Revision
Oct. 15, 2005 C0118-05 Revision
July 10, 2003 C0118-03 Revision
Aug. 10, 1999 C0118-99 Revision