ASTM C1116/C1116M-10

Historical Revision

Standard Specification for Fiber-Reinforced Concrete

$83.00

$83.00

$149.40

$0.00

$0.00

$0.00



Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This specification covers all forms of fiber-reinforced concrete that are delivered to a purchaser with the ingredients uniformly mixed, and that can be sampled and tested at the point of delivery. It does not cover the placement, consolidation, curing, or protection of the fiber-reinforced concrete after delivery to the purchaser.

1.2 Certain sections of this specification are also applicable to fiber-reinforced concrete intended for shotcreting by the dry-mix process when sampling and testing of concrete is possible only at the point of placement. In this case, the sections dealing with batching plant, mixing equipment, mixing and delivery, and measurement of workability and air content, are not applicable.

1.3 This specification does not cover thin-section glass fiber-reinforced concrete manufactured by the spray-up process that is under the jurisdiction of ASTM Subcommittee C27.40.

1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.5 The following precautionary statement pertains only to the test method portion, Sections 15 and 18, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

This specification covers all forms of fiber-reinforced concrete that are delivered to a purchaser with the ingredients uniformly mixed. This specification may also apply to fiber-reinforced concrete intended for shotcreting by the dry-mix process when sampling and testing is possible at the point of placement. It, however, does not cover the placement, consolidation, curing, or protection of the fiber-reinforced concrete after delivery to the purchaser. Materials are classified according to the type of fiber incorporated, which are: Type I, steel fiber-reinforced concrete that contains stainless, alloy, or carbon steel fibers; Type II, glass fiber-reinforced concrete that contains alkali-resistant glass fibers; Type III, synthetic fiber-reinforced concrete that contains synthetic fibers; and Type IV, natural fiber-reinforced concrete that contains cellulose fibers. The fiber-reinforced concretes shall be furnish either by batch mixing or continuous mixing, and shall be free of fiber balls when delivered to the point designated by the purchaser. Tolerances, acceptance criteria, and performance requirements for workability and air content are discussed thoroughly.


SDO ASTM: ASTM International
Document Number C1116
Publication Date July 1, 2010
Language en - English
Page Count 7
Revision Level 10
Supercedes
Committee C09.42
Publish Date Document Id Type View
Aug. 1, 2023 C1116_C1116M-23 Revision
Dec. 1, 2010 C1116_C1116M-10A Revision
July 1, 2010 C1116_C1116M-10 Revision
June 1, 2009 C1116_C1116M-09 Revision
Dec. 15, 2008 C1116_C1116M-08A Revision
Jan. 1, 2008 C1116_C1116M-08 Revision
Dec. 15, 2006 C1116_C1116M-06 Revision
April 1, 2015 C1116_C1116M-10AR15 Reaffirmation