Logo

ASTM C1064/C1064M-23

Current Revision

Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete

$61.00

$61.00

$109.80

$73.00

$73.00

$131.40



Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


Stay effortlessly up-to-date with the latest standard revisions. When new versions are released, they're automatically charged and delivered to you, ensuring seamless compliance.

...

1.1 This test method covers the determination of temperature of freshly mixed hydraulic-cement concrete.

1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.

1.3 The text of this standard refers to notes and footnotes that provide explanatory information. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2)

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


4.1 This test method provides a means for measuring the temperature of freshly mixed concrete. The measured temperature represents the temperature at the time of testing and may not be an indication of the temperature of the freshly mixed concrete at a later time. It may be used to verify conformance to a specified requirement for temperature of concrete.

4.2 Concrete containing aggregate of a nominal maximum size greater than 75 mm [3 in.] may require up to 20 min for the transfer of heat from aggregate to mortar. (See ACI Committee 207.1R Report.4)

SDO ASTM: ASTM International
Document Number C1064
Publication Date Dec. 1, 2023
Language en - English
Page Count 3
Revision Level 23
Supercedes
Committee C09.60
Publish Date Document Id Type View
Dec. 1, 2023 C1064_C1064M-23 Revision
Oct. 1, 2017 C1064_C1064M-17 Revision
Dec. 1, 2012 C1064_C1064M-12 Revision
Dec. 1, 2011 C1064_C1064M-11 Revision
July 1, 2008 C1064_C1064M-08 Revision
Jan. 1, 2005 C1064_C1064M-05 Revision
June 1, 2004 C1064_C1064M-04 Revision
July 10, 2003 C1064_C1064M-03 Revision
Nov. 10, 2001 C1064_C1064M-99 Revision
Nov. 10, 2001 C1064_C1064M-01 Revision